Sense

key

ASC

ASCQ Message name / description

B

30

00

INCOMPATIBLE MEDIA
An attempt was made to move media to a destination element that is

incapable of receiving it. Make sure you are using the correct media

and that it is labeled with the correct barcode.

B

43

00

SCSI MESSAGE ERROR
Detected message error in message processing on the SCSI BUS.

•

Verify termination.

•

Verify SCSI cable connections.

•

Check host status.

•

Restart system.

B

47

00

SCSI PARITY ERROR
SCSI Parity Error detected.

•

Verify termination.

•

Verify SCSI cable connections and cable length.

•

Check host status.

•

Restart the system.

B

48

00

INITIATOR DETECTED ERROR MESSAGE RECEIVED

B

80

01

TRANSFER FULL - AT END OF PLACE
Picker has cartridge in it at end of a place operation (Move Medium

with a target other than the Transfer).

•

Move cartridge to empty storage element using your application

software. Retry command.

•

As a last resort, manually remove the tape from the robotics.

B

80

06

TRANSFER EMPTY - COMMAND ABORTED
Picker does not contain cartridge at end of pick portion of the Move

Medium command.

B

80

10

LOAD RETRY FAILED
Library was unable to successfully load and thread the drive, even after

retries.

•

Check drive alignment.

•

Make sure the correct media for the drive is being used.

•

If cartridge loads in another drive successfully, the original drive

may have failed.

B

80

0B

COMMAND ABORTED BY USER
Informational message. No action is necessary.

B

80

0D

CARTRIDGE PARTIALLY GRIPPED

•

Issue a Move Medium command using your application software to

move the cartridge from the transfer element to an empty storage

element.

•

If necessary, manually clear the media, recalibrate, then inventory

the library.

B

88

C0

TRANSPORT FULL
The CLM contains a cartridge. Issue a command to retrieve the cartridge

from the CLM and place it in either a bin or a tape drive.

B

8C

01

LOAD PORT LATCH FAILURE
The load port door was unlocked, but did not leave its current position

before time-out (30 seconds). This may be due to the door being stuck,

or in the case of a close operation, the operator not moving the door.

HP StorageWorks