Sense

key

ASC

ASCQ Message name / description

5

81

F0

PICKER INVALID COMMAND
Picker hardware commanded to position out of system mechanical limits.

Run the Robotics to Home Position test from the OCP.

5

82

E0

ROTARY INVALID START CONDITION
Rotary hardware condition is unknown. Run the Robotics to Home

Position test from the OCP.

5

82

F0

ROTARY INVALID COMMAND
Rotary axis was commanded to a position out of its legal range. This

is an internal code failure.

•

Verify that the host software application is supported, has up-to-date

patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

5

83

E0

EXTENSION INVALID START CONDITION
Extension hardware condition is unknown. Run the Robotics to Home

Position test from the OCP.

5

83

F0

EXTENSION INVALID COMMAND
Extension hardware was commanded to a position out of the systems

mechanical limits.

•

Verify that the host software application is supported, has up-to-date

patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

5

84

E0

VERTICAL INVALID START CONDITION
Vertical hardware condition is unknown. Run the Robotics to Home

Position test from the OCP.

5

84

F0

VERTICAL INVALID COMMAND
Vertical hardware commanded to position out of system mechanical

limits.

•

Run the Robotics to Home Position test from the OCP.

•

If the problem persists, calibrate the library.

•

Verify that the host software application is supported, has up-to-date

patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

5

85

E0

HORIZONTAL INVALID START CONDITION
Horizontal hardware condition is unknown. Run the Robotics to Home

Position test from the OCP.

5

85

F0

HORIZONTAL INVALID COMMAND
Horizontal hardware commanded to position out of system mechanical

limits.

•

Run the Robotics to Home Position test from the OCP.

•

If the problem persists, calibrate the library.

•

Verify that the host software application is supported, has up-to-date

patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

5

87

F0

DEPTH INVALID START CONDITION
Depth hardware condition is unknown. Run the Robotics to Home

Position test from the OCP.