HP StorageWorks XP Remote Web Console Software User Manual

Page 104

Advertising
background image

Table 33 Cause of Error and the Result of RAID Manager Command (SSB)

Cause of Error

RAID Manager Command

SSB2

SSB1

Because of the shortage of
the pair tables, XP Snapshot
pair cannot be created.

paircreate

9685

B901

B9A8

B9A9

B9AD

B9AE

Because of the shortage of
the differential tables, XP
Snapshot pair cannot be
created.

paircreate

9686

Since the pool is not
available, XP Snapshot pair
cannot be created.

paircreate

9700

When you create multiple XP
Snapshot pairs by specifying
multiple S-VOLs for one
P-VOL, you specified the
pool ID that is different from
the pool ID used by the pairs
that are already created.
Therefore, an XP Snapshot
pair cannot be created.

paircreate

9702

Since the volume you
specified as the P-VOL is
already used by another XP
Snapshot S-VOL, the pair
cannot be created.

paircreate

9703

Since the volume you
specified as the S-VOL is
already used by another XP
Snapshot P-VOL, the pair
cannot be created.

paircreate

9704

Since the volume you
specified as the S-VOL is
already used by another XP
Snapshot S-VOL, the pair
cannot be created.

paircreate

9705

Since the specified XP
Snapshot ID is already used
by another XPp Snapshot
pair, the pair cannot be
created.

paircreate

9706

Since the capacity of the
pair exceeds the licensed
capacity, the pair cannot be
created.

paircreate

9707

The command ended
abnormally because the
command other than the
paircreate command was
issued for the volume in the
pair other than the XP
Snapshot pair.

This error also may be
reported when the command
is executed by specifying an
unsupported parameter.

All commands

9718

All commands

9719

104 Troubleshooting

Advertising
This manual is related to the following products: