background image

Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)

Cause of Error

RAID Manager Command

SSB2

SSB1

The XP Snapshot pair cannot
be created because the
specified consistency group
number is out of the range
of the number that can be
specified.

The snapshot data cannot be
stored because the XP
Continuous Access
asynchronous pair status is
other than PSUS or PSUE
when XP Snapshot (P-VOL)
and XP Continuous Access
asynchronous (S-VOL) share
the volume.

pairsplit

978c

The XP Snapshot pair for
which the consistency group
is specified cannot be
created because the P-VOL
or S-VOL of the XP Business
Copy pair is specified as the
P-VOL of the XP Snapshot
pair.

paircreate

978e

The XP Thin Provisioning
virtual volume, which is
undergoing capacity
expansion, is specified as
the XP Snapshot P-VOL.
Therefore, the XP Snapshot
pair cannot be created.

paircreate

9790

The XP Snapshot pair cannot
be created because the XP
Thin Provisioning V-VOL that
is discarding zero data is
specified as a P-VOL of the
XP Snapshot pair.

paircreate

9793

The command ended
abnormally because the
specified S-VOL used two
mirrors in a 3DC multi-target
or 3DC cascade
configuration, which is a
delta resync configuration
consisting of three XP
Continuous Access Journal
sites.

paircreate

pairsplit

pairresync

pairresync -restore

97a2

The command ended
abnormally because the
specified S-VOL used two
mirrors in a 3DC multi-target
or 3DC cascade
configuration, which is a
delta resync configuration
consisting of three XP
Continuous Access Journal
sites.

paircreate

pairsplit

pairresync

pairresync -restore

97a3

B912