HP StorageWorks XP Remote Web Console Software User Manual

Page 105

Advertising
background image

Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)

Cause of Error

RAID Manager Command

SSB2

SSB1

The command ended
abnormally because the pair
is in the status that the
corresponding command is
not accepted at present.

This error also may be
reported when the command
is executed with specifying
an unsupported parameter.

Since the capacity of shared
memory is insufficient, the
pair cannot be created.

paircreate

971a

Since the attribute of the
specified pool is other than
XP Snapshot, an XP
Snapshot pair cannot be
created.

paircreate

971b

Since the volume you
specified as the P-VOL has
an S-VOL Disable attribute,
an XP Snapshot pair cannot
be restored.

pairresync -

restore

971f

Any errors have occurred
because of the XP Snapshot
operation.

All commands

9720

Since either XP Snapshot or
XP Business Copy Software
is not installed, the
command ends abnormally.

paircreate

pairsplit

pairresync

pairresync -

restore

9721

Because of no additional
shared memory (FCV2, TPF,
Extention1), the command
ends abnormally.

All commands

9723

Because of no additional
shared memory (more than
XP1), the command ends
abnormally.

All commands

9724

Since the LDEV number of
the volume you specified as
the P-VOL is beyond the
specified range, the
command ends abnormally.

All commands

9725

Since you specified the
unmounted volume as the XP
Snapshot P-VOL, the
command ends abnormally.

All commands

9726

Since you specified the
blocked volume as the XP
Snapshot P-VOL, the
command ends abnormally.

9727

Troubleshooting When Using XP RAID Manager 105

Advertising
This manual is related to the following products: