Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)

Cause of Error

RAID Manager Command

SSB2

SSB1

When the XP Snapshot
P-VOL and XP Business Copy
P-VOL share the volume, the
XP Business Copy P-VOL you
specified for the XP Snapshot
P-VOL has consistency group
settings. Therefore, the XP
Snapshot pair cannot be
created.

When the XP Snapshot
P-VOL and XP Business Copy
S-VOL share the volume, you
specified MU number zero
(0) for the XP Snapshot
P-VOL. Therefore, the XP
Snapshot pair cannot be
created.

paircreate

9777

When the XP Snapshot
P-VOL and S-VOL share the
volume, the XP Business
Copy S-VOL you specified
for theXP Snapshot P-VOL
has consistency group
settings. Therefore, the XP
Snapshot pair cannot be
created.

paircreate

9778

When the XP Snapshot
P-VOL and XP Business Copy
P-VOL share the volume, the
XP Business Copy pair was
in the process of
resynchronization.
Therefore, the command
ends abnormally.

paircreate,
pairsplit

977a

When XP Snapshot P-VOL
and XP Business Copy S-VOL
share the volume, the status
of the XP Business Copy pair
is other than PSUS.
Therefore, the command
ends abnormally.

paircreate,

pairsplit

977b

When XP Snapshot P-VOL
and XP Business Copy P-VOL
share the volume, the status
of the XP Business Copy pair
is other than PSUS or PSUE.
Therefore, the XP Snapshot
pair cannot be restored.

pairresync -

restore

977c

When XP Snapshot P-VOL
and XP Business Copy S-VOL
share the volume, the status
of the XP Business Copy pair
is other than PSUS.
Therefore, the XP Snapshot
pair cannot be restored.

pairresync -

restore

977d

pairsplit

977e