HP ProLiant DL380 G4 Server User Manual

Page 17

Advertising
background image

Component identification 17

The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may
report server status differently than the health LEDs because the software tracks more system attributes.

System LED and color

Internal health LED
color

Status

Processor failure,
socket X (Amber)

Red

One or more of the following conditions may exist:

Processor in socket X has failed.

Processor X is not installed in the socket.

Processor X is unsupported.

ROM detects a failed processor during POST.

Amber

Processor in socket X is in a pre-failure condition.

PPM failure, slot X
(Amber)

Red

PPM in slot X has failed.

PPM is not installed in slot X, but the corresponding
processor is installed.

DIMM failure, slot X
(Amber)

Red

DIMM in slot X has failed.

Amber

DIMM in slot X is in a pre-failure condition.

DIMM failure, all slots
in one bank (Amber)

Red

No valid or usable memory is installed in the system.

Overtemperature
(Amber)

Red

The Health Driver has detected a cautionary
temperature level.

The server has detected a hardware critical
temperature level.

Riser interlock
(Amber)

Red

PCI riser cage is not seated.

Online spare memory
(Amber)

Amber Bank

X failed over to the online spare memory bank.

Power converter
module (Amber)

Red

Power converter module has failed.

Fan (Amber)

Amber

Redundant fan has failed.

Red

The minimum fan requirements are not being met. One or
more fans have failed or are missing.

SCSI configuration
error (Amber)*

Red

SCSI cabling or terminator configuration is incorrect for
SCSI backplane.

*This feature applies only to SCSI models.