HP 3Gb SAS Switch for HP BladeSystem c-Class User Manual
Page 40

NOTE:
•
To expand or contract the display for each switch, click the arrow at the far right of the display.
•
In addition to the mouse, the tab, arrow keys, and space bar can be used to select or clear
drives from the zone group.
•
Information about the switch port is included in the display. If the port is connected to a device,
information about the device is displayed. If a tape device is connected to a switch port,
information is shown only for the first tape drive.
•
In dual-domain (redundant switch) environments, select ports on both switches, to provide
access through both switches in the pair.
•
Switch ports without attached storage enclosures can be assigned to a zone group. This allows
you to pre-configure the zone groups and connect additional storage enclosures at a later
time.
•
The following words may be displayed in the navigation tree by the zone group:
◦
Pending Save—until the configuration is saved.
◦
Unassigned—until a server device bay is granted access to the zone group.
•
To assign this zone group to a server device bay, select the server device bay in the navigation
tree and click Modify Zone Access. For more information, see
40
Tasks in the VSM Zoning tab