background image

Update Firmware task

Use this task to install new firmware on the SAS BL Switch. Firmware is pre-installed in the factory,
but an updated, alternative, or preferred version may be available.

After selecting this task, the currently-installed firmware version of each SAS BL Switch in the c-Class
enclosure is displayed in the task section of the screen.

Prerequisites

Before updating firmware, review system requirements and other information in the firmware
release notes, device QuickSpecs, and other user documents.

Before updating firmware, refresh the VSM display to ensure displayed information is current.
Correct any issues before proceeding.

The switch must be reset to activate newly installed firmware. Switch resetting may disrupt the
I/O transaction between servers and storage enclosures.

In single-domain configurations, schedule a maintenance window to power off and then
restart all associated solution devices.

In dual-domain configurations, if both switches have been updated, restart the active
switch and wait for it to complete its power on sequence and I/O to resume before
restarting the passive switch. A maintenance window is not required in dual-domain
configurations, because, when one of the switches is restarted, all I/O will automatically
be passed through the partner switch.

After updating firmware, refresh the VSM display to ensure displayed information is up-to-date.

After updating firmware, be sure to check the status of the device for unexpected issues.
Correct any issues.

IMPORTANT:

When two SAS BL Switches are installed in the same interconnect bay row of a

BladeSystem c-Class enclosure, make sure that they are running the same firmware version.

Update Firmware task

45

Advertising