HP 3Gb SAS Switch for HP BladeSystem c-Class User Manual
Page 71

1.
[Optional] Verify the status of the switch and switch ports. Use the show command to determine
which switch ports are available.
NOTE:
The
bsp
parameter specifies that you want to show “blade switch port” information.
The display of this example is abbreviated, retaining key details. The display shows information
for the switch installed in interconnect bay 7, that none of the switch ports are already included
in a zone group, and that a shared SAS storage enclosure is connected to switch ports 1 and
2.
=> sw local bsp all show detail
Blade Enclosure at BottomC7000
Switch: Local
Blade Switch Port: 71
Port Number: 1
Zoning Status: OK
Presence: Present
Attached Device Type: SAS
Product ID: MSA2012sa
LED Status: Green
Blade Switch Port: 72
Port Number: 2
Zoning Status: OK
Presence: Present
Attached Device Type: SAS
Product ID: MSA2012sa
LED Status: Green
Blade Switch Port: 73
Port Number: 3
Zoning Status: OK
Presence: Absent
LED Status: Off
Blade Switch Port: 74
Port Number: 4
Zoning Status: OK
Presence: Absent
LED Status: Off
.
.
.
Blade Switch Port: 77
Port Number: 7
Zoning Status: OK
Presence: Absent
LED Status: Off
Blade Switch Port: 78
Port Number: 8
Zoning Status: OK
Presence: Absent
LED Status: Off
2.
Create the zone group.
This example shows how to create a zone group named OpenZone that includes ports 1 and
2 on switches in interconnect bays 7 and 8.
=> sw local startupdate
Success
=> sw local create type=zg zonegroupname=OpenZone bsp=71,72,81,82
Success
=> sw local saveupdate
Success
Creating a switch-port zone group
71