HP ProLiant ML350e Gen8 Server User Manual

Page 34

Advertising
background image

Operations 34

CAUTION:

To prevent a server malfunction or damage to the equipment, do not add or remove

the capacitor pack while an array capacity expansion, RAID level migration, or stripe size

migration is in progress.

CAUTION:

After the server is powered down, wait 15 seconds and then check the amber LED

before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do
not remove the cable from the cache module. The cache module is backing up data, and data is

lost if the cable is detached.

To remove the component:

1.

Do one of the following:

o

For tower models, open and remove the bezel ("

Remove the tower bezel

" on page

22

).

o

For rack models, if installed, remove the security bezel (on page

24

).

2.

Power down the server (on page

22

).

3.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

4.

Do one of the following:

o

For tower models, place the server on a flat, level surface with the access panel facing up.

o

For rack models, extend the server from the rack (on page

27

).

5.

Remove the access panel (on page

25

).

6.

If installed, remove the PCI air baffle (on page

28

).

7.

Remove the system air baffle (on page

30

).

8.

If you are removing a capacitor connected to a cache module installed in the system board cache
module connector, first remove any installed PCI cards in slots 3, 4, 5 and 6.

9.

Disconnect the cable from the FBWC module.

10.

Remove the capacitor pack:

o

RPS

Advertising