HP ProLiant DL385 G6 Server User Manual
Page 90
Specifications 90
•
HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
100V to 120V AC
200V to 240V AC
Rated input frequency
50Hz to 60Hz
Rated input current
8.9A at 100V AC
4.3A at 200V AC
Rated input power
857 W at 100V AC input
824 W at 200V AC input
BTUs per hour
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC
input
750 W at 200V to 240V AC
input
Rated peak power
750 W at 100V to 120V AC
input
750 W at 200V to 240V AC
input
•
HP ProLiant 1200 W Power Supply
Specification Value
Input requirements
Rated input voltage
100V to 120V AC
200V to 240V AC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10A at 100V AC
4.9A at 200V AC
Rated input power
930 W at 100V AC input
1348 W at 200V AC input
BTUs per hour
3530 at 120V AC input
4600 at 200V to 240V AC
input
Power supply output
Rated steady-state power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input