MARK HOLES

Select the vent option that your installation will require

and proceed to that section:

Hood mounting screws (4)

13¾”

13¾”

Cabinet front

Center

line

Electrical access

hole (in cabinet

bottom)

Wood shims

(recessed-bottom

cabinets only)

Vertical duct

access hole

9¼”

14

16

1¼”

7¾”

3

11

/

16

11/16”

A. Outside top exhaust

(Vertical duct–3

1

4

x 10

Rectangular)

• Use the diagram or the hood as a template and mark

the locations on the cabinet for ductwork, electrical

wiring and keyhole screw slots .

Cabinet Bottom

7

Wood shims

(recessed-bottom cabinets only)

Cabinet front

Center line

Electrical

access hole

(in wall)

Hood mounting

screws (4)

Horizontal duct

access hole

Cabinet

bottom

13¾”

1¼”

½”

3½”

5

1

4

5

1

4

7¾”

13¾”

B. Outside rear exhaust

(Horizontal duct–3

1

4

x 10

Rectangular)

• Use the diagram or the hood as a template and mark

the locations on the cabinet for ductwork, electrical

wiring and keyhole screw slots .

C. Recirculating (non-vented ductless)

• Use the hood as a template and mark the locations

on the cabinet for the electrical wiring and keyhole

screw slots .

• Since the hood is to be recirculated (not to be vented

outside), do not cut out any vent openings in the wall

or cabinet bottom .

FOR 3

1

4

” x 10” RECTANGLE DUCTED

DISCHARGE INSTALLATIONS:

Attach exhaust adaptor/damper over knockout

opening with two exhaust adaptor screws . Make sure

damper pivot is nearest to top/back edge of hood .

Remove tape from damper flap .

Up to 1” side-to-

side adjustment

Tape

Top/back edge

Exhaust adaptor/damper

(vertical discharge position

shown)

Pivot

6

Installation Instructions

NOTE: The exhaust adaptor/damper can be installed

up to 1 inch on either side of the hood center to

accommodate off-center ductwork . In extreme off-center

installations, one end of the duct connector may need to

be trimmed to clear the electrical cable clamp .