BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT –

Save these instructions for local

inspector’s use .

IMPORTANT –

Observe all governing codes and

ordinances .

Note to Installer –

Be sure to leave these instructions

with the Consumer .

Note to Consumer –

Keep these instructions for future

reference .

Skill level – Installation of this appliance requires basic

mechanical and electrical skills .

Completion time – 1–3 hours

• Proper installation is the responsibility of the installer .

• Product failure due to improper installation is not covered

under the Warranty .

*

IMPORTANT: If a rectangular-to-round

transition adaptor is used, the bottom

corners of the damper will have to

be cut to fit, using the tin snips, in

order to allow free movement of the

damper . Equivalent lengths of duct

pieces are based on actual tests and

reflect requirements for good venting

performance with any hood .

DUCTWORK REQUIREMENTS

WARNING –

Before beginning the

installation, switch power off at service panel and lock the

service disconnecting means to prevent power from being

switched on accidentally . When the service disconnecting

means cannot be locked, securely fasten a prominent

warning device, such as a tag, to the service panel .

FOR YOUR SAFETY:

Questions?

Call

800.GE.CARES (800.432.2737)

or Visit our Website at:

GEAppliances.com

Installation

Range Hood

Instructions

WARNING

TO REDUCE THE RISK OF FIRE,

USE ONLY METAL DUCTWORK.
NOTE: Read the ductwork sections only if you do not have

existing ductwork. If you have existing ductwork, skip to

the “Damage” section and proceed.
The venting system must exhaust to the outside .
This hood can be vented vertically through upper cabinets

or horizontally through an outside wall . Ductwork is not

included .

Exhaust connection:

The hood exhaust has been designed to mate with

standard 3

1

4

” x 10” rectangular ducting .

If a 7” round duct is required, a rectangular-to-round

transition adaptor must be used* . Do not use less than a

7” diameter duct.

Maximum duct length:

For satisfactory air m ovement, the total duct length of a

3

1

4

” x 10” rectangular should not exceed 65 equivalent feet .

NOTE: It’s important that ducting be installed using the

most direct route and with as few elbows as possible .

This ensures clear venting of exhaust and helps prevent

blockages . Also, make sure dampers swing freely and

nothing is blocking the ducts.

Elbows, transitions, wall and roofcaps, etc.,

present additional resistance to airflow and are equivalent

to a section of straight duct longer than their actual

physical size . When calculating the total duct length, add

the equivalent lengths of all transitions and adaptors plus

the length of all straight duct sections . The charts on the

following pages show you how to calculate total equivalent

ductwork length using the approximate feet of equivalent

length of some typical ducts .

WARNING –

TO REDUCE THE RISK

OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable codes and

standards, including fire-rated construction .

B. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment

to prevent back drafting . Follow the heating equipment

manufacturer’s guideline and safety standards such as

those published by the National Fire Protection Association

(NFPA), the American Society for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE) and the local code authorities .

When applicable, install any makeup (replacement) air system

in accordance with local building code requirements . Visit

GEAppliances.com

for available makeup air solutions .

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities .

D. Ducted fans must always be vented to the outdoors .

WARNING –

TO REDUCE THE RISK OF FIRE AND

TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE—

DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR

CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.