TROUBLESHOOTING CHECKLIST

If the hood seems to be operating at high speed when

the control is not set on high, or if ventilation seems

inadequate, check the following:

Knockouts not removed from hood .

Damper blade not opening .

Reduced airflow because the duct is too small or the

duct length is too long .

The duct is blocked .

Undersized or restrictive wall or roof cap .

REPLACE WIRING COVER

Replace the wiring cover .

CONNECT WIRING

Connect house black to hood black wire, house white

to hood white wire, and house ground to hood green/

yellow wire . Securely tighten the strain relief clamp

onto the house wiring .

19

20

17

CONNECT DUCTWORK TO HOOD

Use duct tape to make joints secure and air tight .

Note: Illustration shows rectangular to round duct adapter .

Duct tape

16

REPLACE FILTERS

The installation is complete . Turn on power at service

panel, and test for proper operation .

Installation Instructions

21

WARNING:

Hg

- Lamp contains Mercury. Manage in accord with

disposal laws.

See www.lamprecycle.org or 1-800-435-4448 .

For installation, handling and disposal precautions, refer to

the fluorescent lamp packaging literature .

WARNING:

n

To reduce the risk of electric shock, do not connect electrical

power to the hood without both lamps in place.

CAUTION:

n

Do not touch the hood lamps when they are on. They may

be hot enough to cause injury.

n

To prevent injury from broken lamps, handle lamps carefully

and do not operate hood without lamp lens covers in place.

This hood requires two Compact Fluorescent Lamps (CFL)

with a GU24 base (included), maximum 15 watts .
To change the lamps:

When installing or replacing a lamp, make sure that

power to the light has been turned off . Never allow a

lamp to come into contact with water .

Remove the lens cover by sliding it in a horizontal direction

and pulling it down and away from the hood .

Grasp the lamp by the plastic base portion of the lamp

and unscrew it .

Replace with energy saving GE 15W Compact Fluorescent

Lamp with GU24 base GE Service Part: WB08X10064.

INSTALL LAMPS

FOLLOW ELECTRICAL CODE

Complete the electrical wiring according to National

Electrical Code and local codes .

NOTE: This hood must be permanently grounded .

Connect

house wiring (120 VAC) to hood wiring .

18