Yield monitor 2000, Ag leader technology – Ag Leader Yield Monitor 2000 Operators Manual User Manual
Page 38

Calibrating Distance
Yield Monitor 2000
Ag Leader Technology
June 1997
3-2
Preparing to
Calibrate Distance
You must do the following before you begin calibrating distance:
•
Accurately measure a known distance, setting flags or making a mark at
each end
Notes:
•
A distance of at least 200 feet is desired to obtain an accurate
calibration.
•
For maximum accuracy, calibrate on a ground surface that is at least
somewhat similar to field conditions (you can also calibrate while
harvesting if you know or measure a precise distance in the field).
•
Change to a data load (load with arrow to right of load number L1->)
with no distance.
Follow these procedures to change to a data load.:
Step
Action
1
•
Start a new load by pressing the top UP ARROW key with the
load displayed and scroll past the last load.
or
•
Make an existing load the data load by pressing the MEM key
until “CHANGE TO THIS LOAD?” appears on the display, then
press the YES key.
2
Press the DIST key to display “x FT,” and check that 0 feet are in the
data load. If there are feet in the load, start a new load according to
step 1.