Control valve settings for self-propelled sprayers, Ontrol, Alve – Ag Leader InSight Ver.8.0 Users Manual User Manual
Page 289: Ettings for, Ropelled, Prayers

275
A
PPLICATION
C
ONTROL
V
ALVE
S
ETTINGS FOR
S
ELF
-P
ROPELLED
S
PRAYERS
Flow Control
Valve or
Sprayer
Model (and
year if
applicable)
Control
System
PWM Frequency
Typical Gain Range
Zero Offset
Allowable Error
Valve Response 1
Valve Response 2
Response Threshold
Apache
510/710/1010/1
210 (2006 and
up)
In-line Servo
2%
100%
24%
Use a
starting
value of
5. * See
note
below.
All Case IH
sprayers when
using
AIM Command
AIM Command
Inline Servo
2%
100%
24%
3
Case IH
Surveyor with A-
post
Non-AIM
Command Mode
PWM
12-volt
122
**700-
900
35
2%
Case IH 3320
Non-AIM
Command Mode
PWM 12-volt
122
**700-
900
35
2%
Case IH 4420
with A-post
Non-AIM
Command Mode
PWM 12-volt
122
**700-
900
35
2%
Case IH 3200
(KZCO Valve)
Non-AIM
Command Mode
By-Pass Servo
2%
40%
10%
5
Case IH 4260
with Raven
valve
Non-AIM
Command Mode
By-Pass Servo
2%
100%
24%
3
Case IH 4260
with KZCO valve
Non-AIM
Command Mode
By-Pass Servo
2%
40%
10%
5
Case IH 3150
with Raven
valve
Non-AIM
Command Mode
In-Line Servo
2%
100%
24%
3