The complete instruction manual is on the CD

LM-2

QUICK START GUIDE

Software Installation

It is important to install the provided software on the computer
prior to connecting the LM-2. Failure to do so may lead to
connection complications.

1.

Place the CD that came with your LM-2 in your personal computer.

2.

The software installer will automatically start, follow the prompts to
finish the installation.

3.

Once the software is installed connect one end of the USB cable to
the LM-2 and the other end to your computer.

4.

Confirm the LM-2 is powered up.

5.

Windows will now recognize the device and prompt the “New
Hardware Wizard.” Click Next. (Fig 1)

6.

Select “Install the Device Automatically” and click Next.

7.

A progress screen will appear. During this installation process the
screen below will pop up. Click “Continue Anyway.” (Fig 2)

8.

The last screen will inform you that the unit has been successfully
installed. Click “Finish.” The unit is installed and ready to use.




















Sensor Calibration

1.

Connect the oxygen sensor to the provided sensor cable and then
to the appropriate port on the LM-2. Note: The dual channel LM-2
model allows you to connect both oxygen sensors to the unit at the
same time to do the calibration simultaneously.

2.

Connect the LM-2 to a 12V power source with the provided
cigarette power adapter.

3.

The sensor(s) will start warming up. The LM-2 will display WXX,
where XX is the percentage of temperature reached. Wait for the
sensor to finish warming up.

4.

Next is the calibration procedure. Press and hold the Mode button
until the Configuration Menu appears. Select ‘Calibrate Sensors’
and press the Enter button.

5.

Confirm by selecting ‘Start Sensor Calibration’ and press the Enter
button.

6.

The display will momentarily display ‘Cal’ and then it will switch to
reading a percentage of oxygen. If the oxygen content now differs
from 20.9% by more than 0.4%, repeat the calibration.

7.

The LM-2 is now ready to read A/F.




Instruction Manual


Once the software is installed the manual can be found by clicking on
Start->Programs->LogWorks3->Manuals->LM-2 Manual.