GReddy TURBO KITS: Toyota Celica GTS 2000-02 / MP62 User Manual

Page 8

Advertising
background image

Kit dipstick

guide

OE dipstick

guide

3-5 Kit Oil Dip Stick Installation

(1) Remove the O-ring from the OE dipstick guide and

place it on the Kit dipstick guide.

If the O-ring is damaged, please replace with OEM

part.

〈Part №9〉

(2) Place the Kit dipstick guide in the factory location on

the engine block and attach the bracket to the

supercharger Assy and tighten bolt.

Bracket bolt

3-6 Alternator Installation

(1) Attach the alternator to the lower alternator bracket

installed in step 3-2.

※ Use OEM bolt

(2) Attach the upper alternator bracket to the alternator

and torque the lower alternator bolt.

Use OE bolt on the alternator side of the bracket and

provided bolt for the engine side of bracket.

Upper alternator bracket

Torque spec: M8 bolt 29N・m (290kgf・cm)

M10 bolt 58N・m (580kgf・cm)

〈Parts №6,26〉

3-7 Kit Tensioner Pulley Installation

Rim

Attach the Kit tensioner pulley to the lower

alternator bracket with the spacer between the

pulley and bracket. Use the provided bolt to attach

pulley to bracket.

Place the pulley so the rim faces the bracket.

Use thread lock on the pulley bolt.

〈Parts №4,10,32〉

―8―