Outback Power Systems MATE2 System Controller and Display Installation and User Manual User Manual

Page 108

Advertising
background image

108

ADV/SETTINGS/WARNING

changes made could

adversely effect
system performance

Before entering the

ADVANCED screens, a

warning message appears.

Any changes can always

be undone, different values

entered, or the MATE can

be returned to its factory

default settings.

After pressing the

<INC> soft key until

the password number

141 appears, the ad-

vanced screens for the

FX. Charge Controller,

and MATE become

available.

The advanced FX screens include:

u

FX search sensitivity, pulse length,

and pulse spacing

u

low battery cut-off and cut-in set

points

u

adjustments to the output voltage

u

charger limits

u

absorb, float, refloat, and equalize

settings

u

resetting the FX to factory defaults

u

AC grid usage and limits

u

generator usage and limts

u

AUX functions, including genalert,

loadshed, vent fan, and diversion

functions

u

FX stacking

u

selling voltage and grid tie settings

u

VAC and VDC calibrations

ADV/PASSWORD

enter the password

132
ENTER INC DEC EXIT

ADV-------------------------------------

choose product

FX C C DC MATE

The advanced CC screens include:

u

AUX output function

u

AUX output control

u

programming of both the

FLEXmax60 and FLEXmax 80

Charge Controllers

The advanced MATE screens include:

u

HBX grid use and drop setpoints

and delays, AC input control

u

GRIDUSE weekday and weekend

start and stop times

u

AGS or advanced generator start

functions such as SETUP, QUIET

TIME, VOLT START, LOAD START,

MUST RUN, %SOC, TIMERS, AND

EXERCISE

u

resetting the MATE2M to factory

default values

The ADV(anced) menu allows a user

to more precisely adjust the inverter

and charger functions as well as the

generator function and grid-tie set-

points. The ADV menu is password-

protected requiring the password

141 be entered before accesssing the

screens.

The advanced FLEXnet DC screens include:

u

battery bank capacity

u

enable or disable shunts

u

establish the end of charge amps, end of

charge voltage, and amount of time the charge

parameters must be met

u

AUX functions

u

resetting to factory default and clearing the

data log