INVERTER CONTROL

currently: ON

OFF SRCH ON OK

AC IN HOT KEY

AC INPUT CONTROL

currently: DROP

DROP USE OK

GEN START CONTROL

currently: MAN-OFF

OFF AUTO ON OK

CHARGER CONTROL

currently: OFF

OFF AUTO ON OK

CHARGER MODE CONTROL

global charger mode

BULK EQ OK

INV HOT KEY

SUMMARY SCREENS

MAIN--------------------------

6:54:42P

SUM STATUS SETUP ADV

CC TOTALS 14.5 V

Output 0A 0.000kW

Today 0.0kWH

FX MENU

MODES

MAIN-------------------------

6:54:42PM

SUM STATUS SETUP ADV

STATUS-----------------------

choose device:

FX CC DC MAIN

STATUS/FX/PAGE1---------

choose category:

MODES METER BATT PG2

STATUS/FX/MODE---P00

inv control: ON

CHANGE

DOWN STAT MODE PORT

FX Total 12.6V 97%

Inverting 0.000kW

AC Loads 0.000kW

Buying $ 0.000kW

INVERTER CONTROL P00

currently: ON

OFF SRCH ON OK

STATUS/FX/MODE---P00

inv control: ON

CHANGE

DOWN STAT MODE PORT

AC INPUT CONTROL

currently: USE

DROP USE OK

STATUS/FX/MODE---P00

ac in control: USE

CHANGE

DOWN UP MODE PORT

STATUS/FX/MODE---P00

chr control: AUTO

CHANGE

DOWN UP MODE PORT

CHARGER CONTROL P00

currently: AUTO

OFF AUTO ON OK

STATUS/FX/MODE---P00

chr control: AUTO

CHANGE

DOWN UP MODE PORT

STATUS/FX/MODE---P00

aux control: AUTO

CHANGE

DOWN UP MODE PORT

STATUS/FX/MODE---P00

ac in control: USE

CHANGE

DOWN UP MODE PORT

AUX OUTPUT CONTROL

currently: AUTO

OFF AUTO ON OK

STATUS/FX/MODE---P00

aux control: AUTO

CHANGE

DOWN UP MODE PORT

EQUALIZE CONTROL

eq enabled: NO

START STOP EXIT

FX METERS

MAIN-------------------------

6:54:42PM

SUM STATUS SETUP ADV

STATUS----------------------

choose device:

FX CC DC MAIN

STATUS/FX/PAGE1--------

choose category:

MODES METER BATT PG2

SILENT P00

inv 0.0kw zer 0.0kw

chg 0.0kw buy 0.0kw

DOWN STATUS PORT

STATUS/FX/MODE---P00

eq enabled:

CHANGE

UP MODE PORT

STATUS/FX/METER-—P00

output 122 vac

voltage

DOWN UP TOP PORT

STATUS/FX/METER---P00

input 122 vac

voltage

DOWN UP TOP PORT

AC IN

INV

FIRST PRESS

SECOND PRESS

THIRD PRESS

FOURTH PRESS