Inputs and outputs – Vaisala PTB330 User Manual

Page 129

Advertising
background image

Chapter 7 ____________________________________________________________ Technical Data

VAISALA ______________________________________________________________________ 127

Inputs and outputs

Table 26

Inputs and outputs

General

Supply voltage

10 ... 35 VDC

Supply voltage sensitivity

negligible

Serial I/0

RS-232C, RS-485, RS-422

Pressure units

hPa, mbar, kPa, Pa inHg,
mmH

2

O, mmHg, torr, psia

Acceleration sensitivity

negligible

Pressure connector

M5 (10-32) internal thread

Pressure fitting

barbed fitting for 1/8" I.D. tubing,
quick connector with shutoff
valve for 1/8" hose

Display (optional)

LCD with backlight, graphic
trend display of any parameter

Menu languages

English, German, French,
Finnish, Spanish, Swedish,
Japanese, Russian

Power control

5 VDC to supply voltage

Power consumption @ 20 °C (Uin 24 VDC, one pressure sensor)

RS-232

typ 25 mA

RS-485

typ 40 mA

Uout

typ 25 mA

Iout

typ 40 mA

Display and backlight

+20 mA

Analog output (optional)

Current output

0 ... 20 mA, 4 ... 20 mA

Voltage output

0 ... 1 V, 0 ... 5 V, 0 ... 10 V

Accuracy class differences

Class A

Class B

Resolution 0.01hPa

0.1

hPa

Settling time at power-up
(one sensor)

4 s

3 s

1 s

Response time (one sensor)

2 s

0.2 s (fast measurement mode)

Pressure

500...1100 hPa

50...1100 hPa

Accuracy at +20 °C

±0.30 hPa

±0.40 hPa

Accuracy at -40 ... +60 °C

±0.60 hPa

±0.75 hPa

Advertising