Figure 15, Set_parameter with ack, Figure 16 – Vaisala GMP231 User Manual
Page 57: Get_parameter with nack, Figure 17, Get_parameter with alarm
Advertising

Chapter 5 _______________________________________________________________ I2C Interface
VAISALA ________________________________________________________________________ 55
1403-163
Figure 15
Set_Parameter with ACK
1403-118
Figure 16
Get_Parameter with NACK
1403-117
Figure 17
Get_Parameter with Alarm
NOTE
The alarm can be any of the state bits in the status byte.
Ma
st
e
r
Sl
a
ve
Set_Parameter,Pressure_ID,1013.25
I2C Write
Set_Parameter,Pressure_ID,ACK
I2C Read
Ma
st
e
r
Sl
a
ve
Get_Parameter,CO2_ID
I2C Write
Get_Parameter, CO2_ID,nan,NACK
I2C Read
Ma
st
e
r
Sl
a
ve
Get_Parameter,CO2_ID
I2C Write
Get_Parameter, CO2_ID, 665, Alarm bit =1, ACK
I2C Read
Get_Parameter,Status_ID
I2C Write
Get_Parameter,Status_ID,statusword,ACK
I2C Read