NO MODE

If a User Input terminal or a Function key is activated it

will be ignored.

MNT RST (MAINTAINED RESET)

Maintained reset has four selectable options, in which any or all can be

selected in the edit menu by selecting YES or NO using the UP and
DOWN arrow keys. When using the maintained reset with a small preset
value, the Inhibit should be used with maintained reset, if the signal is
present at the input when the reset is activated.

RATE:

Resets the measurement period. The rate display value will

be the last reading obtained before the reset. The next reading
will occur after the release of the reset and the expiration of the
measurement period. The Rate display will not reset to zero.

PEAK:

Resets the peak value to the current rate value.

VALLEY:

Resets the valley value to the current rate value.

COUNT:

Resets the count value to the programmed reset action.

With Maintained reset, the value is held reset as long as the User Input

or Function key is active. The unit will start updating the appropriate
display when no longer in reset. Maintained reset is level sensitive and
overrides an automatic reset mode.

Note:The user input must NOT be active when selecting an

option.
In this module, the operator may have to enter a second

sub menu for some options before entering the edit menu.
The following flowchart shows only the User portion:

PROGRAM USER MODULE

There are five User Inputs, three external

User Inputs, and two front panel Function
keys, which have a variety of programmable
capabilities. An external User Input is active
when tied to common. A front panel function
key is active when pressed. The options for
each User input are the same, except the two
Function keys (F1 & F2/RST), which DO
NOT have the Program Disable (PGM. DIS.)
option. The operator can select only one
option for each User Input.