MOM RST (MOMENTARY RESET)

Momentary reset has the same four selectable options as Maintained Reset.

With Momentary reset, the value resets when the user input or function key is
activated. The value will start updating (counting) after the reset action has
occurred, even if the user input or function key is still active. Momentary
reset is negative edge sensitive and overrides an automatic reset mode.

RST OUT (RESET OUTPUT)

The operator can select to have Output 1 through Output 5 reset. If the

output is active, it will reset to its inactive state when the user input or
function key is activated. This is a momentary reset.
Note: The Inactive state of an output can be ON or OFF depending on what is

programmed in the Program Outputs Module.

SET OUT (SET OUTPUT)

The operator can select to have Output 1 through Output 5 set. If the output

is inactive, it will go (set) to its active state when the user input or function key
is activated. If an output is programmed with a time delay and this User Input
is activated, the output will NOT latch, but will time out after the time delay
value expires. This is a momentary reset.
Note: The Active state of an output can be ON or OFF depending on what is

programmed in the Program Outputs Module.

VIEW DS1 (VIEW/ FREEZE DISPLAY)

When a User Input is activated, an indication display will be viewed and the

numeric value for that display will be held. If the operator is in the main display
loop, the unit will advance to the indication display to be viewed. If more than
one user input is used for this option, the input with the highest priority will be
the only one that will hold (freeze) the display. Also, it will be the only input,
when activated, that will advance to the indication display from the main
display loop. Any other user input programmed, will only advance in the
indication display loop. The priority order is F2, F1, USR INP3, USR INP2,
and USR INP1 with F2 the highest priority. DS1 selects display 1, DS2 display
2, DS3 display 3, and DS4 display 4. The values that are viewed/frozen on the
display are determined by what is selected in the Program Displays Module.

Note: If an external and a front panel user input are both selected for this option,

the display will be viewed, but the numeric value will NOT freeze when either
user input is activated.

CHG DSP (CHANGE DISPLAY)

In the indication display loop, when a user input is activated, the indication

display will toggle to the next indication display. The change display is a
momentary action.

CNT LD (COUNTER LOAD)

When a user input is activated, the count value is reset to the counter load

value regardless of the reset action mode. The counter load is a maintained
action.

PRINT RQ (PRINT REQUEST)

When a user input is activated, the unit transmits all the information

selected in the Print Options Module via the RS 485 serial port. The print
request is a maintained action.

SKIP P1 (SKIP PRESET 1)

Output 1 will NOT activate and an automatic reset will NOT occur, when

the count value equals preset 1 if the user input is active. This mode is
typically used with the Automatic Reset at output 1 or output 2 mode, or the
reset after timed output 1 or 2 mode. The skip preset 1 is maintained.

PGM. DIS. (PROGRAM DISABLE)

Only one external User Input can be used for this option. This option used

with the Program Disable DIP switch can limit operator access to
programmable parameters (Refer to Operator Accessible Functions With
Program Disable section). The program disable is maintained.

-20-