Specifications – Red Lion LEGEND User Manual

Page 48

Advertising
background image

SPECIFICATIONS

1. DISPLAY: 2x8, 0.3" (7 mm) high characters, negative image transmissive

LCD, with yellow/green or red LED backlighting.

2. POWER:

AC Operation: 115/230 VAC ±10%, 50/60 Hz,

10 VA, switch selectable.

DC Operation: +12 VDC ±20% @ 250 mA.

3. MEMORY: Non volatile memory retains all programming information.

Count and Preset values are written to non volatile memory when power is
interrupted. All other programming parameters are written to memory when
programming mode is exited. If power is removed while in the programming
menus, the parameters are restored to previously saved settings.

4. SENSOR POWER: +12 VDC ±25% @ 100 mA.
5. INPUTS A and B: DIP Switch selectable to accept count pulses from a

variety of sources including switch contacts, outputs from CMOS or TTL
circuits, and all standard RLC sensors.
LOGIC: Input trigger levels V

IL

1.5 V

MAX

; V

IH

3.75 V

MIN.

Current sinking: Internal 7.8 K

Ω pulled up internally to +12 VDC ,

I

MAX

1.9 mA.

Current sourcing: Internal 3.9 K

Ω pull down, 7.3 mA @ 28 VDC

MAX.

Debounce: Damping capacitor provided for switch contact bounce.

Limits count speed to 50 Hz and input pulse widths, 10 msec min.

MAGNETIC PICKUP:

Sensitivity: 200 mV peak.
Hysteresis: 100 mV.
Input impedance: 3.9 K

Ω @ 60 Hz.

Maximum input voltage: ±50 Vp
Note: For magnetic pickup input, the sink/source DIP switch must be in

the SRC position.

6. RATE ACCURACY: +0.01%.
7. RATE MINIMUM INPUT FREQUENCY: 0.01 Hz.
8. CONTROL INPUTS:

Programmable user inputs (3): Internal 10 K

Ω pull up to +5 VDC,

V

IL

1.0 V

MAX

; V

IH

4.0 V

MIN

, response time

10 msec max.

Inhibit: Internal 10 K

Ω pull up to +5 VDC, V

IL

1.0 V

MAX

;

V

IH

4.0 V

MIN.

-46-

DIMENSIONS In inches (mm)

PANEL CUT-OUT

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 3.0" (76.2)H x 4.0" (101.6)W.

Advertising