DC Characteristics

Function
DCV, DCI, and
Resistance

Digits
6

1

2

6

1

2

5

1

2

5

1

2

4

1

2

Readings/s
0.6 (0.5)
6 (5)
60 (50)
300
1000

Additional
Noise Error

0% of range
0% of range
0.001% of range
0.001% of range
0.01% of range

System Speeds

[ 9 ]

Function Change
Range Change
Autorange Time
ASCII readings to RS-232
ASCII readings to GPIB
Max. Internal Trigger Rate
Max. External Trigger Rate to Memory
Max. External Trigger Rate to GPIB

26/sec
50/sec
<30 ms
55/sec
1000/sec
1000/sec
1000/sec
900/sec

Operating Characteristics

[ 8 ]

[10]
[10]

Measurement Noise Rejection
60 Hz ( 50 Hz )
[ 5 ]
DC

CMRR

Integration Time
100 PLC / 1.67s (2s)
10 PLC / 167 ms (200 ms)
1 PLC / 16.7 ms (20 ms)
0.2 PLC / 3 ms (3 ms)
0.02 PLC / 400

µ

s (400

µ

s)

140 dB

Normal Mode Rejection

[ 6 ]

60

dB

[ 7 ]

60

dB

[ 7 ]

60

dB

[ 7 ]

0 dB
0 dB

[12] Accuracy specifications are for the voltage measured at
the input terminals only. 1 mA test current is typical. Variation
in the current source will create some variation in the voltage
drop across a diode junction.

DC Voltage
Measurement Method:

A/D Linearity:
Input Resistance:
0.1 V, 1 V, 10 V ranges
100 V, 1000 V ranges
Input Bias Current:
Input Terminals:
Input Protection:

Resistance
Measurement Method:

Max. Lead Resistance:
(4-wire ohms)
Input Protection:

DC Current

Shunt Resistor:
Input Protection:

Continuity / Diode Test
Response Time:
Continuity Threshold:

DC:DC Ratio
Measurement Method:
Input

HI-LO

Reference HI-Input LO
Input to Reference

Continuously integrating, multi-slope III
A/D converter.
0.0002% of reading + 0.0001% of range

Selectable 10 M

or >10 G

[11]

10 M

±

1%

< 30 pA at 25°C
Copper alloy
1000 V on all ranges

Selectable 4-wire or 2-wire ohms.
Current source referenced to LO input.
10% of range per lead for 100

, 1 k

ranges. 1 k

per lead on all other ranges.

1000 V on all ranges

0.1

for 1A, 3A. 5

for 10 mA, 100 mA

Externally accessible 3A, 250 V fuse
Internal 7A, 250 V fuse

300 samples/sec with audible tone
Adjustable from 1

to 1000

Input HI-LO / Reference HI-LO
100 mV to 1000 V ranges
100 mV to 10 V ranges (autoranged)
Reference LO to Input LO voltage < 2 V
Reference HI to Input LO voltage < 12V

Measuring Characteristics

Teflon is a registered trademark of E.I. duPont deNemours and Co.

Autozero OFF Operation
Following instrument warm-up at calibration temperature

±

1°C

and <10 minutes, add 0.0002% range additional error + 5

µ

V.

Settling Considerations
Reading settling times are affected by source impedance,
cable dielectric characteristics, and input signal changes.

Measurement Considerations
Agilent recommends the use of Teflon

â

or other high-impedance,

low-dielectric absorption wire insulation for these measurements.

[ 1 ]

Specifications are for 1-hour warm-up at 6

1

2

digits.

[ 2 ]

Relative to calibration standards.

[ 3 ]

20% overrange on all ranges, except 1000 Vdc, 3 A range.

[ 4 ]

Specifications are for 4-wire ohms function, or 2-wire

ohms using Math Null. Without Math Null, add 0.2

additional error in 2-wire ohms function.

[ 5 ]

For 1 k

unbalance in LO lead.

[ 6 ]

For power-line frequency

±

0.1%.

[ 7 ]

For power-line frequency

±

1%, subtract 20 dB.

For

±

3%, subtract 30 dB.

[ 8 ]

Readings speeds for 60 Hz and ( 50 Hz ) operation,

Autozero

Off.

[ 9 ]

Speeds are for 4

1

2

digits, Delay 0, Autozero OFF,

and Display OFF. Includes measurement and data

transfer

over

GPIB.

[ 10 ]

Add 20

µ

V for dc volts, 4

µ

A for dc current, or

20 m

for resistance.

[ 11 ]

For these ranges, inputs beyond

±

17V are

clamped through 100 k

(typical).

8

Chapter 8 Specifications