Kenwood TS-590S User Manual

Page 8

Advertising
background image

8

Reference:

To implement data communications, turn this function OFF.

4.1.4 Data VOX Settings

Set whether or not to use the VOX function for the audio output from the rear terminal.

Menu No.

Function

Set value

69

Data VOX

ON or OFF

The default setting is OFF.

Caution:
¾ When this function is ON, all sounds created by the computer other than the

intended audio transmissions are also transmitted, so be careful.

¾ When using this function for the first time, we recommend connecting a dummy

load to the TS-590S to perform checks and adjustments.

4.1.5 Data VOX Delay Time Setting

Set the VOX Delay Time Setting when using the Data VOX function.

Menu No.

Function

Setting range

70

Data VOX delay time

0 to 100

The default setting is 50.

4.1.6 Data VOX Gain Setting

Set the VOX Gain Setting when using the Data VOX function.

Menu No.

Function

Setting range

71

Data VOX gain for the USB audio input

0 to 9

The default setting is 50.

4.1.7 Allocating DATA SEND Functions to PF Keys

Set the DATA SEND functions to the PF keys to test the transmission of audio input

from the rear terminal. In this example, the [PF A] key has been set.

Menu No.

Function

Set value

79

Front panel PF A key assignment

205

The default setting is 200 (VOICE1).