7.2 Installation

Do not make any changes or install
connections that are not included in this
handbook. Failure to follow the connection
instructions that are given in the handbook
may create serious safety hazards for
people and for the installation.

Do not change the wiring in the product
as it is supplied to you. Failure to follow
this instruction may create serious safety
hazards for people and for the installation,
and will also invalidate the guarantee.

Keep a connection diagram for future
reference.

If using the washer kit, the spray support
should be installed before positioning
the pan & tilt and the wiring. For further
explanations see the specific handbook for
the kit.

Fig. 24

7.2.1 Connecting the cables to the base

Insert the cables into the cable glands and, holding
the base at about 20cm from the support, lock
the cable glands with a torque wrench setting of
5Nm. The cable glands are suitable for cables with
diameters of between 5 and 10mm.

Fig. 25

For smaller cables (from 3 to 7mm) use the
supplied gaskets.

Fig. 26