9.1.15 Factory Default

To restore the factory settings relative to the network,
user access and camera configuration follow this
procedure:
• Turn on the unit.
• Open the cover of the dip-switches.
• Locate dip-switch 1 (01) and lower it, 1 (ON) value.
• Wait for the temporary shutdownf of the LEDs (02).
• Bring dip-switch 1 up, 0 (OFF) value.
• Close the cover

01

02

Fig. 75

9.2 VTTunnel

The application works only with java™. If
java™ is not installed download the latest
version at www.java.com.

The application can be connected only to
the first interface of the network. Leave
only the network cable connected to the
pan & tilt.

The execution of the application requires
computer administrator privileges. The
following message may appear on the
screen: You have to execute javaw as
administrator. In this case the execution
properties of the file in the java installation
folder must be modified.

In order to connect the web camera you must use the
program VTTunnel, available in the Tools menu.
When the program starts, a list of networked devices
will be shown. To connect to the camera select the
pan & tilt desired and press the Connect button.
Once the connection is established, the web page of
the IP camera can be reached at 192.0.0.64.
When the operations on the camera are done, you
can close the connection by clicking the Disconnect
button. It is possible to connect to one camera at a
time, so you need to disconnect from the P&T unit
before operating on a different unit.

Fig. 76