3 electrical, 4 communications, 5 protocols – Videotec ULISSE MAXI NETCAM User Manual

Page 43: 6 environment, 7 certifications

Advertising
background image

Instruc

tions manual - English - EN

41

15.3 Electrical

Suitable for use with network cameras
Input voltage:

- 230Vac, 50/60Hz, 100W
- 24Vac, 50/60Hz, 100W
- 120Vac, 50/60Hz, 100W

Current consumption:

- 230Vac, 0.4A
- 24Vac, 4A
- 120Vac, 0.8A

Camera power supply: 12Vdc (800mA)
4 self-powered alarm inputs
2 clean contacts: 30Vdc max or30Vac, @ 1A

15.4 Communications

Ethernet connection: IEEE 802.3 100Base-Tx

15.5 Protocols

ONVIF, S profil

15.6 Environment

Indoor/Outdoor
Operating temperature (with heater): -10°
(14°F)/+60°C (140°F)
Resistant to salty fog (EN50130-5, EN60068-2-52)
Surge immunity: up to 2KV line to line, up to 4KV line
to earth (Class 4)

15.7 Certifications

CE: EN60950-1, EN60950-22, EN61000-6-4, EN55022
Class A, EN50130-4
IP66 EN60529