Section 1. Features and Specifications

3

RELATED DOCUMENTS

The following MagTek documents are relevant to this product:

99875163

MCP, Serial Transport Protocol, Reference Manual

99875164

Communication Protocol, Driver Reference Manual

99875168

IntelliStripe 320, Command Reference Manual


MOTORIZED TRANSPORT

The Reader has a command-driven motorized transport. The transport keeps the card from the
user during a transaction but returns the card when the transaction is completed.

RS-232 INTERFACE

The device can communicate to the host through an RS-232 interface. Once the host
communicates to the device on this interface the device will no longer be able to communicate
on any other interface until it is power cycled or reset. The device uses 8 data bits, 1 stop bit,
even parity. The device can automatically sync to baud rates 9600, 14400, 19200, 28800, 38400,
57600 and 115200. See MCP Driver Reference Manual, Part Number 99875164, MCP Serial
Transport Protocol Reference Manual, Part Number 99875163 and IntelliStripe 320 Command
Reference Manual, part number 99875168, for more details.

USB INTERFACE

The device can communicate to the host through a USB interface. It is compliant with the USB
2.0 full-speed device specification and is compatible with any host that is compliant with USB 1,
2 or 3.

Once the host communicates to the device on this interface the device will no longer be able to
communicate on any other interface until it is power cycled or reset. The device uses vendor
identifier 0x0801 and product identifier 0x000B. The device contains a manufacturer string
descriptor with a value of “MagTek”. The device contains a product string descriptor with a
value of “IntelliStripe 320”. The device contains a programmable serial number string
descriptor. The device does not get its power from the USB port; it needs to be self powered.
When using the USB port, power must be applied directly to the PCB via the power connector or
the host connector. See MCP Driver Reference Manual, Part Number 99875164, MCP Serial
Transport Protocol Reference Manual, Part Number 99875163 and IntelliStripe 320 Command
Reference Manual, part number 99875168, for more details.

TEST LED

A Test LED, designated D5 will blink green when the unit is powered up. This indicates that the
unit is in its standard operating mode and is fully operational. This feature allows field
technicians to quickly verify that the device is operational.