LED INDICATORS

Table 3-1 describes the LED indicator conditions for check and card reading operations. The
LED indicator is located below the slot where the check is first inserted for reading.

Table 3-1. LED indicators

LED INDICATOR

DESCRIPTION

OFF Power

off

SOLID GREEN

Ready to read check or card

OFF

→ SOLID RED

Check read error

OFF

→ SOLID GREEN

Good read

FLASH GREEN

Needs initialization*

FLASH RED/GREEN

Magnetic Interference Detected

FLASH RED/GREEN

Data sensor blocked (motor does not run)*

FLASH RED

Motor sensor blocked (motor does not run)*

*Refer to “Section 4. Troubleshooting Guide.”


CLEANING

Clean the outside of the MICRImage unit with a soft, damp cloth and wipe with a dry cloth.

Caution

To avoid damaging the read head, do not get the inside of the
check or card paths wet.

Use the Cleaning Card, P/N 96700004, on the MSR as described below. Use the Cleaning Swab,
P/N 97200078, to clean the Imager Scan Bar as shown and described below.

Opening the Unit

To open the check path and Imager, grip the access latch, and pull up and then back as shown in
Figure 3-3.

MSR Cleaning Card

Orient the cleaning card similar to Figure 3-2. Swipe the card two or three times to clean the
head.