Section 4. Troubleshooting Guide


17


04 Analyze

data


Analyze the data received by the PC:
◊ If the data is good, continue to step 15.
◊ If the data contains one or more '?', continue to step 06.
◊ If the data is missing characters, continue to step 07.
◊ If the data is garbled, continue to step 08.
◊ If the data is good but not what is expected, continue to step 09.



05 Verify

parameters


Use MICRbase to verify the following parameters:
• "Send Data After Error" - if this option is set to NO, the MICRImage Reader will not send

any data after a read error. Use SET-MICR to change this option to YES.

• "Use CTS/DSR" - if this option is set to USE, the MICRImage Reader will not send any data

unless the CTS and DSR signals are enabled. Use SET-MICR to change this option to
IGNORE.


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 13.



06 Read

error


Possible causes for this problem are:
• Interference - the MICRImage Reader may be too close to a monitor, AC adapter or

magnetic device. Move the MICRImage Reader away from the source of interference.

• Printing problem - the check being read may not meet the requirements of the ANSI

Standards. Use one the sample checks provided by MagTek .

• Feeding the check - do not hold on to the check as it goes around the path. Release the check

immediately after the MICRImage Reader "grabs" it. Also, make sure that the front end is
not tilted up while the check is being read.


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 10.