Appendix A. CPEC200 Diagnostics

notes on bit 8 and on

irga_status, which may give additional information

about the IRGA problem.

pump_flow_OK

Boolean variable

pump_flow_OK = True if the pump flow (pump_flow) is

within 10% of the setpoint

PUMP_SETPT. It is set to False if it is outside

this range.

The

PUMP_SETPT check is performed continuously and pump_flow_OK is

set accordingly. If the CPEC200 is in EC mode and

pump_flow_OK is false,

bit 6 of

diag_cpec will be set to indicate there is a problem with the pump

flow. If the CPEC200 is not in EC mode,

pump_flow_OK is ignored. See

notes on bit 6.

pump_tmpr_OK

Boolean variable

pump_tmpr_OK = True if the pump is within its range (0°C

to 55°C) and is set to

False if it is outside this range.

This check is performed continuously, and

pump_tmpr_OK is set

accordingly. If the CPEC200 is in EC mode, bit 5 of

diag_cpec will be set if

pump_tmpr_OK = False to indicate there is a problem with the pump

temperature. If the CPEC200 is not in EC mode,

pump_tmpr_OK is ignored.

See notes on bit 5.

buff_depth_OK

Boolean variable

buff_depth_OK is equivalent to bit 4 of diag_cpec. If the

datalogger processing falls too far behind,

buff_depth_OK =False and bit 4 of

diag_cpec will be set. See notes on bit 4.

valve_flow_OK

Boolean variable

valve_flow_OK is defined only if the CPEC program is

configured to use a valve module. See Section, 4.2.3, Valve Module, for

details.

If the valve (zero/span) flow (

valve_flow) is within its normal range,

valve_flow_OK = True but = False if it is outside this range. This check is

performed only if a valve is selected (

valve_number > 0).

The variable

valve_flow_OK is ignored in EC mode, but if the CPEC200 is

not in EC mode, bit 3 of

diag_cpec will be set if valve_flow_OK = False to

indicate there is a problem with the valve flow. See notes on bit 3.

valve_tmpr_OK

Boolean variable

valve_tmpr_OK is defined only if the CPEC program is

configured to use a valve module. See Section 4.2.3, Valve Module, for details.

If the valve module temperature

valve_tmpr is within its operating range (0°C

to 60°C),

valve_tmpr_OK = True but will = False if it is outside this range.

This check is performed continuously, and Boolean variable

valve_tmprOK is

set accordingly.

The variable

valve_tmpr_OK is ignored in EC mode, but if the CPEC200 is

not in EC mode, bit 2 of

diag_cpec will be set if valve_tmpr_OK= False,

indicating there is a problem with the temperature of the valve module. See

notes on bit 2.

A-7