Campbell Scientific CPEC200 Closed-Path Eddy-Covariance System User Manual

Page 78

Advertising
background image

Appendix C. Output Variables

TABLE C-1. Values stored in table ts_data

Compile

Switch

Variable

Name

Units

Description

cell_press

kPa

Pressure in the sample cell

diff_press

kPa

Differential pressure (sample cell, relative to ambient)

pump_flow

LPM

Sample pump speed, converted to volumetric flow rate

V

valve_number

Valve number (0 to 6); determines which zero/span valve is

selected

V

valve_flow

LPM

zero/span flow

D

CO2_signal

Relative strength of the infrared signal in the CO

2

absorption

band

D

H2O_signal

Relative strength of the infrared signal in the H

2

O absorption

band

D

source_tmpr

ºC

Temperature measured inside the source housing

D

pump_control

Pump speed control variable; can be from 0 (off) to 1 (full speed)

D

pump_press

kPa

Pressure measured at the sample pump inlet

D

pump_tmpr

ºC

Temperature of the pump

D

ControlBits

Status of heaters and fans (see Appendix D, Control Bits, for

details)

D, V

SequenceStep

Status of the zero/span sequence (see TABLE 6-1 for details)

D, V

valve_tmpr

ºC

Temperature of the valve module

D, V

valveControl

Zero/span flow control valve; can be from 0 (closed) to 1 (open)

D, V, S

scrub_press

kPa

Pressure measured at the scrub pump outlet

D, V, S

scrub_tmpr

ºC

Temperature of the scrub module

D

BattVolt

V

Supply voltage; measured inside datalogger after diode voltage

drop

D

process_time

µs

Time to process the scan (a copy of ProcessTime from the Status

table)

D

buff_depth

Number of scans in the pipeline buffer that have not yet been

processed (a copy of BuffDepth from the Status table)

flux

The online flux calculations are stored in table

flux. A record is written to this

table at the end of every output interval (30 min). Space is allocated on the

memory card for 9,600 records (200 days at one record per 30 min). The CPU

has storage allocated for 480 records (10 days).

Most of the values stored in table

flux are always stored, but some are

dependent on the settings for program constants. See Section 5.4.2 Compile

Switches, for details on setting program constants.

The first six values (

Hs through u_star) are the basic online flux calculations.

The next five values (

Ux_Lag_Avg through sonic_samples) are averages of

the sonic anemometer outputs. These are averages of the values that have been

lagged to align the sonic and IRGA data. They are filtered to include only

those data for which there are no sonic diagnostic flags.

The next six values (

CO2_Lag_Avg through irga_samples) are the

corresponding lagged averages of the EC155 data.

The next two values (

pump_flow_Lag_avg and pump_OK_samples) are the

corresponding lagged averages for the pump flow.

C-2