Table 8. formats for entering numbers in crbasic – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 114

Section 7. Installation
114
CRBasic Example 6.
Proper Program Structure
'Declarations
'Define Constants
Const
RevDiff = 1
Const
Del = 0 'default
Const
Integ = 250
Const
Mult = 1
Const
Offset = 0
Declare constants
'Define public variables
Public
RefTemp
Public
TC(6)
'Define Units
Units
RefTemp = degC
Units
TC = DegC
Declare public variables,
dimension array, and declare
units.
Declarations
'Define data tables
DataTable
(Temp,1,2000)
DataInterval
(0,10,min,10)
Average
(1,RefTemp,FP2,0)
Average
(6,TC(),FP2,0)
EndTable
Define data table
'Begin Program
BeginProg
'Set scan interval
Scan
(1,Sec,3,0)
'Measurements
PanelTemp
(RefTemp,250)
TCDiff
(TC()...Offset)
Measure
'Processing (None in this
'example)
Scan loop
'Call data table
CallTable
Temp
Call data table
'Controls (None in this
'example)
'Loop to next scan
NextScan
'End Program
EndProg