3 loggernet setup, Figure 103: pakbus network addressing – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 344

Section 8. Operation
344
Table 82. PakBus-LAN Example Datalogger-Communications Settings
Software→
Device Configuration Utility (DevConfig)
Tab→
Deployment
Sub-Tab→
Datalogger
ComPort Settings
Advanced
Setting→
PakBus Adr
COM1
COM2
Is Router
Sub-Setting→
Baud Rate
Neighbors
1
Baud Rate
Neighbors
1
Datalogger ↓
Begin:
End:
Begin:
End:
CR800_1
1
115.2K Fixed
2
2
115.2K Fixed
3
4
Yes
CR800_2
2
115.2K Fixed
1
1
Disabled
No
CR800_3
3
115.2K Fixed
1
1
115.2K Fixed
4
4
Yes
CR800_4
4
115.2K Fixed
3
3
Disabled
No
1
Setup can be simplified by setting all neighbor lists to Begin: 1 End: 4.
8.5.6.3 LoggerNet Setup
Figure 110: LoggerNet Network-Map Setup: COM port
In LoggerNet Setup, click Add Root and add a ComPort. Then Add a
PakBusPort, and (4) CR800 dataloggers to the device map as shown in figure
LoggerNet Device-Map Setup