Appendix A. CRBasic Programming Instructions

465

 

A.5.8 SDI-12

Read More! See SDI-12 Sensor Support

(p. 173).

SDI12Recorder 
Retrieves the results from an SDI‐12 sensor. 

Syntax 

SDI12Recorder(Dest, SDIPort, SDIAddress, SDICommand,

Multiplier, Offset)

SDI12SensorSetup 
Sets up the datalogger to act as an SDI‐12 sensor 
 
SDI12SensorResponse 
Holds the source of the data to send to the SDI‐12 recorder. 

Syntax 

SDI12SensorSetup(Repetitions, SDIPort, SDIAddress,

ResponseTime)

SDI12SensorResponse(SDI12Source)

A.5.9 Specific Sensors

ACPower 
Measures real ac power and power‐quality parameters for single‐, split‐, and 
three‐phase 'Y' configurations. 

Syntax 

ACPower(DestAC, ConfigAC, LineFrq, ChanV, VMult, MaxVrms,

ChanI, IMult, MaxIrms, Reps)

DANGER ac power can kill. User is responsible for ensuring connections to ac
power mains conforms to applicable electrical codes. Contact a Campbell
Scientific applications engineer for information on available isolation
transformers.

CS110 
Measures electric field by means of a CS110 electric‐field meter. 

Syntax 

CS110(Dest, Leakage, Status, Integ, Mult, Offset)

CS110Shutter 
Controls the shutter of a CS110 electric‐field meter. 

Syntax 

CS110Shutter(Status, Move)

CS616 
Enables and measures a CS616 water content reflectometer. 

Syntax 

CS616(Dest, Reps, SEChan, Port, MeasPerPort, Mult, Offset)