FOR AC-VERSION

(MULTI HOOK-UP); Fig. 15, 15a

Unit #1

Unit #1

Unit #2

Unit #3

1

. Remove the COVER SCREWS (1) and COVER (2) from

each ELECTRICAL BOX

(3).

2. See AC Version Electrical Hook-up for Unit #1 of the Multi

hook-up.

3. Install SENSOR WIRE GROMMET (4) and FLUSH VALVE

SENSOR WIRE

(5) into the COVER (2) of each unit. Insert

the flush valve sensor wire connector into the CENTER

CIRCUIT BOARD RECEPTOR

(6) on each unit. Fig. 15a.

4. Remove the SPLIT PLUG (7a) from the SENSOR WIRE

GROMMET

(7) on the left side of each ELECTRICAL BOX (3).

5. Take the 10 ft. EXTENSION WIRE (8) from Unit #2 and

insert one end of the EXTENSION WIRE CONNECTOR

(9)

through the SENSOR WIRE GROMMET

(7) on left side of Unit

#1. Insert EXTENSION WIRE

(8) into SPLIT PLUG (7a). Push

SPLIT PLUG

(7a) into SENSOR WIRE GROMMET (7) to seal.

Insert EXTENSION WIRE CONNECTOR

(9) into LOWER

CIRCUIT BOARD RECEPTOR

(10). Fig. 15a.

6. Insert other end of EXTENSION WIRE (8) into SENSOR

WIRE GROMMET

(7) on left side of Unit #2. Insert that

EXTENSION WIRE CONNECTOR

(9) into the LOWER

CIRCUIT BOARD RECEPTOR

(10) of Unit #2. Fig. 15b.

7. On Unit #2 ELECTRICAL BOX (3) remove ROUND

KNOCK-OUT

(11) on the bottom of the box by pressing a

flathead screwdriver into the center of the ROUND

KNOCK-OUT

(11). Fig 15b.

8. Insert additional SENSOR WIRE GROMMET (12) included

with Unit #2 into the knock-out opening in the bottom of the

ELECTRICAL BOX

(3). Take the 10 FT. EXTENSION WIRE

(8) from Unit #3 and insert one end into the SENSOR WIRE

GROMMET

(12) in the bottom of the ELECTRICAL BOX (3) of

Unit #2. Insert EXTENSION WIRE CONNECTOR

(9a) into

TOP CIRCUIT BOARD RECEPTOR

(13) on Unit #2 . Fig.

15b.

9. Insert the other end of the EXTENSION WIRE (8) from Unit #3

into the SENSOR WIRE GROMMET

(7) on the left side of Unit

#3. Insert EXTENSION WIRE CONNECTOR

(9) into LOWER

CIRCUIT BOARD RECEPTOR

(10) on Unit #3.

10. Repeat Steps 7 to 9 as necessary for additional Multi-AC

Units.

11. Once all wire connections are made. Install the COVER (2)

and COVER SCREWS

(1) onto each ELECTRICAL BOX (3).

Fig. 15

Fig. 15a

Fig. 15b

12

9

T O P

T O P

T O P

2

7a

7

8

3

6

1

5

4

9

T O P

10

SENSOR WIRE

CONNECTOR

SENSOR

WIRE

FROM UNIT #2

Unit #2

7a

7

8

3

9a

T O P

12

7

12

8

8

8

8

12

11

10

9

SENSOR WIRE

CONNECTOR

FROM

UNIT #3

BACK OF BOX (3)

FROM UNIT #1

REMOVE KNOCK-OUT (11),

INSERT WIRE GROMMET (12)

1

2

SENSOR

WIRE

SENSOR

WIRE

6

10

7

6

10

13

7

6

10

13

13

M968550 REV. 1.6