Recommended tools; fig. 2, Prior to installation, Roughing-in dimensions – American Standard SELECTRONIC 6068.26X User Manual

Page 3: General description

Advertising
background image

RECOMMENDED TOOLS; Fig. 2

Fig. 2

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Teflon Tape

Flat Blade Screwdriver

Adjustable Wrench

Tape Measure

Hacksaw

Tubing Cutter

File

For Sweat Connection; Solder and Torch

2.5mm Hex Wrench

1.5mm Hex Wrench

1

2

3

4

5

6

7

9

10

8

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.

1. Water Closet

2. Drain line

3. Water supply line

• Flush all water lines prior to operation (

See Step 4). Dirt

and debris can cause flush valve to run continuously.

• With the exception of Supply Stop Inlet, DO NOT use pipe

sealant or plumbing grease on any valve component or

coupling!

• Protect the chrome or special finish on chrome plated

items.

DO NOT USE toothed tools on finished surfaces to install or

service these valves. Also see “Care and Cleaning” section

of this manual.

• This product contains mechanical and/or electrical

components that are subject to normal wear. These

components should be checked on a regular basis and

replaced as needed to maintain the valve’s performance.

IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.

• Water supply lines must be sized to provide an
adequate volume of water for each fixture.

2

Fig. 1

Roughing-in Dimensions

GENERAL DESCRIPTION:

10'

Concealed Flushometer

for 1-1/2" Spud Fixtures

SELECTRONIC™

PROXIMITY TOILET

FLUSH VALVE

Exclusive, self cleaning piston-type flush

valve with proximity operation and manual

override. Operates on DC (batter y)or

AC power. Recommended operating

pressure 25psi (flowing) to 80 psi (static).

Can install left or right-handed. Detection

Zone can also be adjusted manually, or

with optional remote control.

-C-L-

51mm (2)

+ WALL THICKNESS

51mm

(2)

152mm

(6) MIN.

71mm

(2-3/4) DIA.

483mm

(19) MAX.

25mm (1) MAX.

160mm

(6-1/4)

OVERRIDE

BUTTON

160mm

(6-1/4)

406mm

(16) MAX.

127X127mm

(5X5 CUTOUT

FOR BOX)

127mm

(5) MAX.

432mm

(17 MAX.)

19mm

(3/4.)

289 TO 403mm

(11-3/8 MIN. TO

15-7/8 MAX.)

*FOR LOCATION OF INLET

SUPPLY ON BACK INLET

FIXTURES,REFER TO FIXTURE

BEING INSTALLED

FOR CORRECT HEIGHT FROM

FINISHED FLOOR

73 TO 137mm

(2-7/8)MIN. TO

(5-3/8) MAX.

403 TO 441mm

(15-7/8) MIN. TO

(17-3/8) MAX.

FINISHED WALL

CONCEALED BACK

SPUD TOILET

EXPOSED BACK

SPUD TOILET

TOP OF RIM

TOP SPUD

TOILET

TOP OF

FIXTURE

SENSOR

SUPPLY

DN 25mm

(1) I.P.S.

115mm-134mm

(4-1/2 TO 5-1/4)

*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6

"

(152mm) min.

above fixture. Consult Codes for details.

73 TO 111mm

(2-7/8 TO

4-3/8)

292mm

(11-1/2) MAX.

51mm

(2)

51mm

(2)

-C-L-

*

WALL THICKNESS

MAXIMUM

DETECTION ZONE

400mm-800mm

(15-3/4 TO 31-1/2)

15˚

19mm

(3/4.)

TOP OF

FIXTURE

M968550 REV. 1.6