Note: The detection distance is preset and is ideal for

most installations. Should an adjustment be required

follow the steps below.

1. Remove FRONT PANEL (1). See Step 9 for

removing front panel instructions.

2. Remove the four COVER SCREWS (2) and COVER

(3) from ELECTRICAL BOX (4). Fig. 18.

3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT

BOARD.

(6).

4. Keeping hands away from the front of the sensor,

reconnect the GREY SENSOR WIRE

(5) and quickly

hang the FRONT PANEL

(1) onto the ELECTRICAL

BOX

(4). Do not secure the FRONT PANEL (1) at this

time.

Note: You have 5 seconds after connecting cable

to begin program process.

5. While the SENSOR CONTROL LED (6) is blinking

slowly, place your hand 1 to 2 in. (30-50mm.) in front of

the sensor.

Fig. 19.

6. When the LED (6) stops blinking and stays "ON",

move your hand to the desired position from sensor

(detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and

hold in place until the LED

(6) begins to blink again. Fig.

19a.

Note: Maximum Detection Zone is 15-3/4" to 31-1/2",

(400 to 800mm ) from sensor.

7. Once the SENSOR CONTROL LED (6) begins to

blink again, remove your hand from the detection zone.

When the flashing stops, the detection distance is set.

8. Replace COVER (3). Tighten COVER SCREWS (2)
firmly.

9. Replace the FRONT PANEL (1). See Step 9 for

instructions on installing front panel.

10. Actuate the FLUSH VALVE:

A) Cover sensor with hand for 10 seconds.

NOTE:

Stand outside of sensor detection aera.

B) Remove hand from in front of the sensor, unit will

flush in approximately 3 seconds.

HOW TO SET DETECTION RANGE
(If Required) ; Fig. 18 & 19

Fig. 19

Fig. 19a

15

1" - 2" (30mm - 50mm)

BLINKING LED

6

MAXIMUM

DETECTION ZONE

400mm TO 800mm

(15-3/4" TO 31-1/2")

BLINKING LED

Fig. 18

1

2

5

3

4

5