Configuring rmon history – Allied Telesis AT-S95 WEB User Manual

Page 223

Advertising
background image

Viewing Statistics

Managing RMON Statistics

Page 223

Configuring RMON History

The RMON History Page contains information about samples of data taken from ports. For example, the samples
may include interface definitions or polling periods.

To view RMON history information:

1.

Click Statistics > RMON History. The RMON History Page opens:

Figure 154:RMON History Page

The RMON History Page contains the following fields:

History Entry No. — Displays the history control entry number.

Source Interface — Displays the interface from which the history samples were taken. The possible field

values are:

Port — Specifies the port from which the RMON information was taken.

Trunk — Specifies the trunk from which the RMON information was taken.

Sampling Interval — Indicates in seconds the time period that samplings are taken from the ports. The field

range is 1-3600. The default is 1800 seconds (equal to 30 minutes).

Sampling Requested— Displays the number of samples to be saved (see Max. No. of Samples to Keep in

the Add RMON History Page). The field range is 1-65535. The default value is 50.

Current Number of Samples — Displays the current number of samples taken. This number should be

equal to or close to the number of samples requested. If the number of samples exceeds the requested
number, the device discards the older samples until the current number equals the requested amount.

Owner — Displays the RMON station or user that requested the RMON information. The field range is 0-20

characters.

2.

Click Add. The Add RMON History Page opens:

Advertising