Allied Telesis AT-WA7500 User Manual
Page 246

9 - Additional Access Point Features
246
sdvars set nextpoweruptime
Purpose:
Sets the nextpoweruptime command to set
the internal variable nextpoweruptime to a
countdown time so that when 0 is reached,
the access point will reboot. When the
nextpoweruptime counter reaches 0, the
access point checks the value of the
setactivepointers variable, takes the
appropriate action, and then reboots.
Note
If you need to terminate the reboot, you can do so by setting
nextpoweruptime to 0 if it has not already been reached by the
countdown. By resetting nextpoweruptime to 0, the timer is
stopped so the unit does not reboot.
Syntax:
sdvars set nextpoweruptime
dd:hh:mm:ss
where dd:hh:mm:ss is how far in the future the reboot is to begin.
dd is days.
hh is hours.
mm is minutes.
ss is seconds.
Example:
To reboot the access point 2 hours from now, enter:
sdvars set nextpoweruptime 00:02:00:00