Fresh water, Metering device (option), Sweeping (b 250 ri only) – Karcher B 250 R I Bp User Manual

Page 22: Bulk waste flap, Stopping sweeping, Program selection switch, Info button, Settings, Operations menu

Advertising
background image

-

6

Open the cover of the fresh water reser-
voir.

Fill fresh water (max. 60 °C) until 15 cm
below the upper edge of the tank.

Pour in detergent.

Close the cover of the fresh water res-
ervoir.

Note:
Fill up the fresh water tank completely prior
to the initial start-up to bleed the water pipe
system.
With automatic fill of fresh water reser-
voir (option)
Note:
It is recommended to use a hose that is
equipped with an Aquastop coupling on the
appliance side. This minimises the spout-
ing of water when the hose is disconnected
after the filling process.

Connect the hose to the automatic fill-
ing system and open the water supply
(max. 60 °C, max. 5 bars).

Wait briefly - the automatic filling sys-
tem will interrupt the water supply when
the tank is full.

Shut off the water supply and discon-
nect the hose from the appliance.

Detergent is added to the fresh water on
the way to the cleaning head with the help
of a dosaging device.
Note:
The dosing unit can be used to add 3% de-
tergent at maximum. With higher dosage
the detergent must be put into the fresh wa-
ter tank.

Place the canister with the detergent in
the trough behind the seat.

Unscrew the canister lid.

Insert the suction hose of the dosing
equipment into the canister.

Note:
– The appliance is equipped with a fresh

water indicator in the display. If the
fresh water tank is empty, the function
of adding detergent gets deactivated.
The cleaning head continues to work
without liquid supply.

– Detergent addition is also stopped

when the detergent can is empty. Indi-
cator lamp: "detergent tank empty"
glows red. Only fresh water is supplied
to the cleaning head.

The sweeper picks up loose dirt before
cleaning the floor.
ATTENTION
Risk of damage to the sweeper.
Do not sweep in packing tapes, wires or

similar objects.

Only drive over steps with a maximum

height of 2 cm with the B 250 RI mod-
els.

The dust filter can get blocked or germs

can form in it. Use the sweeper only to
sweep dry surfaces.

WARNING

Risk of injury!
Suction turbine, side brushes and filter
cleaner continue to run for a while after
switching off.

Switch on "sweeping" button.

The sweeper is activated. The indicator
lamp "sweeping" is on during the opera-
tions.

The bulk waste flap can be raised to sweep
in larger objects (up to max. 6 cm height).
DANGER

Risk of injury on account of electric shock.
Raise the bulk waste flap only when there
is no person standing close by.

Press the pedal for raising the bulk
waste flap.

Note:
The vacuuming and sweeping performance
is lower when the bulk waste flap is raised.
Hence, raise the bulk waste flap only when
needed.

Set "sweeping" button to "0".

The sweeper is deactivated. Once you
have stopped sweeping, the dust filter is
cleaned for approx. 15 seconds. The indi-
cator lamp "dust filter shaking" glows.

1 Transport mode

Driving to the Place of Use.

2 Eco mode

Wet clean the floor (with reduced brush
speed) and vacuum up wastewater
(with reduced suction).

3 Normal mode

Wet clean the floor and vacuum up dirt
water.

4 Increased brush contact pressure

Wet clean the floor (with increased
brush contact pressure) and vacuum up
dirt water.

5 Intense mode

Wet clean the floor and allow the deter-
gent to react.

6 Vacuum mode

Suck in the dirt fleet.

7 Polishing mode

Polishing the floor without the applica-
tion of liquid.

8 Manual cleaning

Apply liquid detergent using the wall-
ceiling-floor nozzle (optional) and vacu-
um it again.

Use the Info button to select the menu
items and do the settings.
– Turning the button to the right/left

scrolls through the menus forward/
backward.

– The selected setting gets accepted by

pressing the button.

You can make the settings for the different
cleaning programs in the operator menu.
Different parameters can be set based on
the cleaning program. The settings are
done using the Info button.

Release emergency-stop button by
turning.

Sit on the seat and set main switch to
“1”.
The display shows the battery charging
status and the fresh water level.

Select cleaning program.

Call the operator menu by turning the
info button.

Select the desired parameter by turning
the Info button. The currently set value
is displayed as a bar.

Press Info button, the bar display blinks.

Reset the parameter by turning the Info
button between "min" and "max".

Accept modified setting by pressing the
Info button or wait till the set value is ac-
cepted automatically.

Application

Detergent

Routine cleaning of all water
resistant floors

RM 745
RM 746

Routine cleaning of glossy
surfaces (e.g. granite)

RM 755 ES

Routine cleaning and basic
cleaning of industrial floors

RM 69 ASF

Routine cleaning and basic
cleaning of fine stoneware
tiles

RM 753

Routine cleaning of tiles in
sanitary areas

RM 751

Cleaning and disinfection in
sanitary areas

RM 732

Removal of coating from all
alkali-resistant floors (e.g.
PVC)

RM 752

Removal of coating from li-
noleum floors

RM 754

Fresh water

Metering device (option)

Sweeping (B 250 RI only)

Bulk waste flap

Stopping sweeping

Program selection switch

1

2

3

4

5

6

7

8

Info button

Settings

Operations menu

22