Self-diagnosis display – Sony DCR-IP210 User Manual

Page 192

Advertising
background image

192

Self-diagnosis display

C:21:00

Five-digit display

Cause and/or Corrective Actions

• You are using a battery pack that is not an

“InfoLITHIUM” battery pack.

c Use an “InfoLITHIUM” battery pack (p. 196).

• Moisture condensation has occurred.

c Remove the cassette and leave your camcorder for at

least one hour to acclimatize (p. 201).

• The video heads are dirty.

c Clean the heads using the cleaning cassette (optional)

(p. 202).

• A malfunction other than the above that you can service

has occurred.

c Remove the cassette and insert it again, then operate

your camcorder. Do not perform this operation if
moisture starts to condense (p. 201).

c Disconnect the power cord of the AC power adaptor or

take out the battery pack. After reconnecting the power
source, operate your camcorder.

• A malfunction that you cannot service has occurred.

c Contact your Sony dealer or local authorized Sony

service facility and inform them of the 5-digit code.
(example: E:61:10)

If you are unable to rectify the problem even if you try corrective actions a few times,
contact your Sony dealer or local authorized Sony service facility.

Your camcorder has a self-diagnosis display
function.
This function displays the current condition of
your camcorder as a five-digit code (a combination
of a letter and figures) on the LCD screen. If a five-
digit code is displayed, check the following code
chart. The last two digits (indicated by ss) will
differ depending on the state of your camcorder.

LCD screen or Viewfinder

Self-diagnosis display

• C:ss:ss

You can service your camcorder
yourself.

• E:ss:ss

Contact your Sony dealer or local
authorized Sony facility.

C:04:ss

C:21:ss

C:22:ss

C:31:ss
C:32:ss

E:20:ss
E:61:ss
E:62:ss

Advertising
This manual is related to the following products: