Confirming/saving the measurement results – Sony STR-DH520 User Manual

Page 33

Advertising
background image

33

GB

D:\NORM'S JOB\SONY HA\SO120020\STR-DH520_PMRF
02\4263361112_GB\GB04CON_STR-DH520-U2.fm

masterpage: Right

STR-DH520

4-263-361-11(2)

Pre

p

ar
ing the

R

eceive

r

The table below provides measurement status
shown on the display panel.

* The corresponding speaker indicator lights up in

the display panel during measurement.

Tips

• You can also select the calibration type you want

and perform the Auto Calibration by using the
“CUSTOM” in AUTO CAL menu (page 35).

• You can change the unit of distance in

“DIST.UNIT” in SPEAKER menu (page 58).

To cancel Auto Calibration

The Auto Calibration function will be
canceled when you perform the following
during the measurement process:
– Press ?/1.
– Press the input buttons or turn the INPUT

SELECTOR on the receiver.

– Change the volume level.
– Press MUTING or

.

– Connect headphones.
– Press AUTO CAL again.

1

Confirm the measurement
result.

When the measurement process is
completed, the result appears on the
display panel with a beep sound.

2

View the measurement result.

Press

V/v repeatedly to select the item.

Then, press

.

3

Save the measurement result.

Select “SAVE.EXIT” in step 2.
“COMPLETE” appears on the display
panel and the settings are saved.

4

Disconnect the optimizer
microphone from the receiver.

Note

If you reposition your speaker, we recommend that
you perform Auto Calibration again to enjoy the
surround sound.

Tip

The size of a speaker (LARGE/SMALL) is
determined by the low frequency characteristics.
The measurement results may vary, depending on
the position of the optimizer microphone and
speakers, and the shape of the room. It is
recommended that you apply the measurement
results. However, you can change those settings in
the SPEAKER menu (page 54). Save the
measurement results first, then try to change the
settings.

Measurement for

Display

Speaker existence

TONE

Speaker gain, distance, frequency
response

T. S. P.*

Subwoofer gain and distance

WOOFER*

3: Confirming/saving the
measurement results

Measurement process
[Display]

Do this

Completes properly

[SAVE.EXIT]

Proceed to step 2.

Fails

[E -

xxx xx

]

See “When error
codes appear”
(page 34)
.

• EXIT

Exits the setting process without saving the
measurement results.

• WARN CHK

Displays warning related to the
measurement results. See “Checking the
warning message” (page 34).

• SAVE.EXIT

Saves the measurement results and exits the
setting process.

• RETRY

Performs the Auto Calibration again.

continued