Setting the Low Battery warning level (Mode 3)

When the 416 is not powered by an OBB-2, it is possible

to set the threshold at which the Low Battery warning is

triggered. It can be set anywhere between 20.0 and 29.9

volts.

• Change from Mode 1 to Mode 3 by pressing the

“MODE” button twice.

• Press the “SET“ button. The currently set Low Battery

warning level is displayed for 3 seconds.

• To change the level, press the “SEL“ button 3 times to

select the 2nd voltage digit or 4 times to select the 3rd

voltage digit. The selected digit will blink.

• Adjust the blinking digit with the “SET“ button.

• Once the 2nd and 3rd voltage digits are set as

required, press the “SEL“ button once to exit the

adjustment mode.