Controller N2000

NOVUS AUTOMATION

3/9

*These parameters can be viewed but not changed if the cycle is
protected.

**Requires a key combination to access the cycle.

Press

P

to advance and

to go back in the menu cycle.

Keep pressing the

P

or

key to move fast forward or backward.

Press

and

P

simultaneously to move from one cycle to the next

one.

At the end of each cycle the controller returns to the operation cycle.

PROGRAM SECURITY

Each menu cycle can be locked (protected) by pressing

and

simultaneously for 3 seconds. Press

and

for 3 seconds to

unlock. A short blink of the display confirms the lock/unlock change.
This will alternately lock or unlock the

and

keys to avoid

tampering.

For further protection, the unlock operation through the keypad may
be disabled by changing the position of an internal strap inside the
controller:

When PROT is OFF, the user is allowed to lock and unlock the
cycles using the keypad as explained above. If PROT is ON, the
cycles lock/unlock operation is disable.

CONFIGURATION

INPUT TYPE SELECTION

Select the input type (in parameter “tYPE

tYPE

tYPE

tYPE”) from Table 1 below.

TYPE

CODE

CHARACTERISTICS

J

0

0

0

0

Range: -50 to 760 °C (-58 to 1400 ºF)

K

1

1

1

1

Range: -90 to 1370 °C (-130 to 2498 ºF)

T

2

2

2

2

Range: -100 to 400 °C (-148 to 752 ºF)

N

3

3

3

3

Range: -90 a 1300 °C (-130 a 2372 ºF)

R

4

4

4

4

Range: 0 a 1760 °C (32 a 3200 ºF)

S

5

5

5

5

Range: 0 to 1760 °C (32 to 3200 ºF)

Pt100

6

6

6

6

Range: -199.9 to 530.0 °C (-328.0 to 986.0 ºF)

Pt100

7

7

7

7

Range: -200 to 530 °C (-328 to 986 ºF)

8

8

8

8

J linearization. Programmable range: -110 to 760 °C

9

9

9

9

K linearization. Programmable range: -150 to 1370 °C

10

10

10

10

T linearization. Programmable range: -160 to 400 °C

11

11

11

11

N Linearization. Programmable range: -90 a 1370 °C

12

12

12

12

R Linearization. Programmable range: 0 a 1760 °C

13

13

13

13

S linearization. Programmable range: 0 to 1760 °C

14

14

14

14

Pt100 linearization. Prog. Range:-200.0 to 530.0 °C

4-20 mA

No linear

15

15

15

15

Pt100 linearization Prog. Range:-200 to 530 °C

0 to 50 mV

16

16

16

16

Linear. Programmable indication -1999 to 9999

4-20 mA

17

17

17

17

Linear. Programmable indication -1999 to 9999

0 to 5 Vdc

18

18

18

18

Linear. Programmable indication -1999 to 9999

4 to 20 mA

19

19

19

19

Square Root Extraction

Table 1 - Input Types

OUTPUTS, ALARMS AND DIGITAL INPUTS CONFIGURATION

The controller input/output channels can assume multiple functions,
depending on configuration: control output, alarm output, digital
output, digital input, and PV or SV analog retransmission. These
channels are identified as I/O1, I/O2, I/O3, I/O4, I/O 5 and I/O6.

The basic controller model comes loaded with:

I/O1 and I/O2 - SPDT relay output;

I/O3 and I/O4 – SPST relay output;

I/O5 - analog output (0-20 or 4-20 mA), pulse 10 V max, digital I/O;

I/O6 – Digital Input;

The function code of each I/O can be selected among the options on
Table 2. Only valid function codes are displayed for each I/O (for
example, I/O1, which is a relay, can be configured with functions 0 to
5 only; on the other hand, I/05 can perform all 16 functions).

The description for the functions follows:

CODE 0 - No function. The I/O channel programmed with code 0
will not be used by the controller. It is available to be used by serial
communication as digital output.

CODES 1 to 4 - Alarm output - Available for all I/O channels
(except I/O6). The selected channel can be used as output to
Alarms 1 to 4.

CODE 5 - PWM control output - Available for all I/O channels
(except I/O6).

CODE 6 - Digital input - Standard for I/O5 and I/O6.

Closed: Manual control
Opened: Automatic control

CODE 7 - Digital input - Standard for I/O5, I/O6 and

F

key.

Start/Stop input (“rvn

rvn

rvn

rvn”: YES / no).

Closed: outputs enabled
Opened: outputs disabled

CODE 8 - Digital input - Standard for I/O5, I/O6 and

F

key.

Closed: remote SP (4-20 mA in remote SP input)
Opened: main SP (internal programmed SV)

CODE 9 - Digital input - Standard for I/O5, I/O6 and

F

key.

Opened: enables R&S program

Closed: holds R&S program (the program resumes when the contact
is opened again)

CODE

I/O TYPE

I/O FUNCTION

0

0

0

0

Digital Output

Digital Output to be set by the serial comm.

1

1

1

1

Digital Output

Alarm 1 Output

2

2

2

2

Digital Output

Alarm 2 Output

3

3

3

3

Digital Output

Alarm 3 Output

4

4

4

4

Digital Output

Alarm 4 Output

5

5

5

5

Digital Output

PWM Control Output

6

6

6

6

Digital Input

Automatic/Manual mode change

7

7

7

7

Digital Input

Run/Stop mode change

8

8

8

8

Digital Input

Select Remote Set Point Input

9

9

9

9

Digital Input

Executes/Holds selected ramp and soak profile

10

10

10

10

Digital Input

Enable/Disable R&S profile 1 selection

11

11

11

11

Analog Output

0 to 20mA Analog control output

12

12

12

12

Analog Output

4 to 20mA Analog control output

13

13

13

13

Analog Output

0 to 20mA PV retransmission

14

14

14

14

Analog Output

4 to 20mA PV retransmission

15

15

15

15

Analog Output

0 to 20mA SP retransmission

16

16

16

16

Analog Output

4 to 20mA SP retransmission

Table 2 - I/O channel functions

CODE 10 - Digital input - Standard for I/O5, I/O6 and

F

key.

Selects R&S program 1. Used to alternate between the main
Setpoint and a second Setpoint defined by the R&S program 1.

Closed : selects program 1
Opened: uses main Setpoint

CODE 11 - Analog control output - I/O5 only. 0-20 mA control
output.

CODE 12 - Analog control output - I/O5 only. 4-20 mA control
output.

CODES 13 to 16 - Analog retransmission. I/O5 only. Configures I/O5 to
output a 0-20 mA or 4-20 mA analog signal proportional to PV or SP.