Goulds Pumps 3296 EZMAG - IOM User Manual

Page 31

Advertising
background image

Installation

Suction-piping checks

Check

Explanation/comment

Checked

Flush all suction piping before you This reduces the risk of pump
connect it to the pump.

operation problems.

Check that the suction piping fit-

tings and joints are airtight and
have no leaks.
Check that the distance between

This minimizes the risk of cavita-

the inlet flange of the pump and

tion in the suction inlet of the

the closest elbow is at least two

pump due to turbulence.

pipe diameters.

See the Example sections for il-
lustrations.

Check that elbows in general do

See the Example sections for il-

not have sharp bends.

lustrations.

Check that the suction piping is

The suction piping must never

one or two sizes larger than the

have a smaller diameter than the

suction inlet of the pump.

suction inlet of the pump.

Install an eccentric reducer be-

See the Example sections for il-

tween the pump inlet and the

lustrations.

suction piping.
Check that the eccentric reducer

See the example illustrations.

at the suction flange of the pump
has the following properties:
• Sloping side down
• Horizontal side at the top
When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the Mesh holes with a minimum diam-

suction piping.

eter of 1/16 in. (1.6 mm) are
recommended.

If more than one pump operates

This recommendation helps you

from the same liquid source,

to achieve a higher pump perfor-

check that separate suction-piping mance.
lines are used for each pump.
If necessary, make sure that the

suction piping includes a drain
valve and that it is correctly in-
stalled.

Liquid source below the pump

Check

Explanation/comment

Checked

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Check that the suction piping

slopes upwards from the liquid
source to the pump inlet.
If the pump is not self-priming,

Use a foot valve with a diameter

check that a device for priming the that is at least equivalent to the
pump is installed.

diameter of the suction piping.

Liquid source above the pump

Check

Explanation/comment

Checked

Check that an isolation valve is

This permits you to close the line

installed in the suction piping at a

during pump inspection and main-

distance of at least two times the

tenance.

pipe diameter from the suction

Do not use the isolation valve to

inlet.

throttle the pump. Throttling can
cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Model 3296 EZMAG Installation, Operation, and Maintenance Manual

29

Advertising